Doosan DX225LC-3 — Operation in Extreme Heat

Formation of scale and rust in cooling system occurs more rapidly in extremely high temperatures. Change antifreeze each year to keep corrosion inhibitor at full strength. If necessary, flush cooling system periodically to keep passages clear. Avoid use of water with a high alkali content which increases scale and rust formation. 2. Check level of battery electrolyte daily. Keep electrolyte above plates to prevent damage to batteries. Use a slightly weaker electrolyte solution in hot climates. Batteries self-discharge at a higher rate if left standing for long periods at high temperatures. If machine is to stand for several days, remove batteries and store in a cool place.

IMPORTANT Do not store acid type storage batteries near stacks of tires. Acid fumes can damage rubber. 3. Service fuel system as directed in “Check Fuel Level” on page 4-26 and “Check for Leaks in Fuel System” on page 4-27 of this manual. Check for water content before filling fuel tank. High temperatures and cooling off cause condensation in storage drums. 4. Lubricate as specified in Periodic Service Chart and Table Section 4, in this manual or Lubrication Decal on machine. 5. Do not park machine in sun for long periods of time. If possible, park machine under cover to protect it from sun, dirt and dust. A. Cover machine if no suitable shelter is available.

Protect engine compartment and hydraulics from dirt and debris. B. In hot, damp climates, corrosion will occur on all parts of machine and will be accelerated during rainy season. Rust and paint blisters will appear on metal surfaces and fungus growth on other surfaces. C. Protect all unfinished, exposed surfaces with a film of preservative lubricating oil. Protect cables and terminals with ignition insulation compound. Apply paint or suitable rust preventive to damaged surfaces to protect them from rust and corrosion. Operation 3-71 DX225LC-3