LONG TERM STORAGE When a machine is taken out of service and stored for a time exceeding 30 days, steps must be taken to protect the machine. Leaving equipment outdoors exposed to the elements will shorten its life. An enclosure will protect the machine from rapid temperature changes and lessen the amount of condensation that forms in hydraulic components, engine, fuel tank, etc. If it is not possible to put the machine in an enclosure, cover it with a tarpaulin. EX1300542 Check that storage site is not subject to flooding or other natural disasters. Figure 145 After the machine has been positioned for storage and the engine stopped, perform the following operations:
Before Storage Keep the excavator in the position shown in Figure 145 to prevent rust of the hydraulic piston rods. Repaint necessary areas to prevent oxidation. Inspect for damaged, loose or missing parts. Wash and clean all parts of machine. Store the machine in an indoor, stable place. If stored outside, cover with a waterproof tarp. Perform lubrication procedures on all grease points. Apply a coating of light oil to the exposed plated metal surfaces (such as hydraulic cylinder rods, etc.) and to all the control linkage and control cylinders. (Control valve spools, etc.) Remove battery from the excavator to be fully charged and stored.
Inspect the coolant recovery tank and radiator to make sure the antifreeze level in the system is correct. Make sure that antifreeze concentration is enough for the lowest temperature anticipated during storage. Seal all external openings (i.e. engine exhaust outlet, crankcase and hydraulic breather, fuel vent line, etc.) with tape wide enough to cover the opening, regardless of size. NOTE: When sealing with tape, be sure to extend tape approximately one inch (25 mm) beyond opening to insure a good seal. Operation 3-77 DX225LC-3