Doosan DX225LC-3 — Check for Leaks in Fuel System

WARNING Stop engine when refueling. AVOID DEATH OR SERIOUS INJURY Turn engine coolant heater "OFF" before filling fuel, to prevent a fire or explosion. 1. At end of each workday, fill fuel tank. Add fuel through fuel fill tube (1, Figure 19). When working at a temperature of 0°C (32°F) or higher, use ASTM No. 2-D or its equivalent. At temperatures below 0°C (32°F) use ASTM No. 1-D or its equivalent. NOTE: Only use Ultra Low Sulfur Diesel (ULSD) fuel and API-CJ-4/ACEA-E9 grade engine oil. 2. Make sure that fuel fill hose is grounded to the excavator before fueling begins. 3. Check the amount of fuel in the tank by observing the fuel tank sight gauge (2, Figure 19). NOTE:

See “Fluid Capacities” on page 4-18. for capacity. 4. The excavator may be equipped with the optional battery operated fuel fill pump. The pump assembly is in the hydraulic pump compartment. Put the suction hose of the pump into the fuel resupply tank. Turn the switch in the pump compartment "ON", and the fuel will be pumped into the excavator fuel tank. NOTE: See “Fuel Transfer Pump (Optional)” on page 4-96, for further information. 5. Do not overfill the tank. 6. Securely tighten cap after fueling. NOTE: If breather holes (3, Figure 20) in cap are clogged, a vacuum may form inside the tank preventing proper fuel flow to engine. Keep holes in fuel cap clean. 3 3 NOTE:

Be careful not to damage the fuel level gauge on the fuel tank by allowing it to becoming stained from thinner or oil. Figure 20 FG018302 Check for Leaks in Fuel System 1. Perform an inspection of engine compartment to verify that fuel system is not leaking. If any is noted, determine source of leak and repair. Inspection, Maintenance and Adjustment 4-27 DX225LC-3