Doosan DX225LC-3 — Check Water Separator & Pre Fuel Filter (Fuel Prefilter) and Drain Water as Required

Check Water Separator & Pre Fuel Filter (Fuel Prefilter) and Drain Water as Required AM H H NOTE: If water in fuel warning symbol (Figure 21) on display monitor comes "ON", drain the collected water in fuel prefilter. E F C C rpm Min Max s DIG ISO USB Min Max FG018303 Figure 21 1. A fuel prefilter is inside the left rear side access door. 2. Open the access door on left side of the machine. Figure 22 3. It is necessary to drain collected water if bowl is full of water or sediment. 4. Position a small container under fuel prefilter. Drain water or sediment by opening drain valve (2, Figure 23) on bottom of bowl (1). NOTE:

Dispose of drained fluids in compliance with all applicable environmental regulations. 1 2 5. Close drain valve. close open FG000438 Figure 23 DX225LC-3 Inspection, Maintenance and Adjustment 4-28 FG019441 9441