Doosan DX225LC-3 — Check Oil Level of Swing Reduction Device

Check Oil Level of Swing Reduction Device 2 1 WARNING The gear oil is very hot after the machine has been operating. Shut all systems down and allow them to cool. Before fully removing any motor case inspection, port plug, etc., loosen the plug slightly to allow pressurized air to escape. AVOID DEATH OR SERIOUS INJURY FG020080 NOTE: When checking level, use a dipstick and always remove and wipe it clean before making final level check. Figure 24 1. Remove dipstick (1, Figure 24) and wipe the oil from the dipstick with a cloth. 2. Insert dipstick (1, Figure 24) fully into dipstick tube. 3. When dipstick is pulled out, oil level must be between "HIGH" and "LOW" marks on dipstick. NOTE:

If oil is above "HIGH" mark on dipstick, some must be drained to proper level. L H 4. If the oil does not reach the "L" mark on the dipstick, add oil through fill port (2, Figure 24). FG000419 Figure 25 5. If the oil level exceeds the "H" mark on the dipstick, release the drain plug (3, Figure 26). Drain the excessive oil into an approved container. NOTE: Dispose of drained fluids in compliance with all applicable environmental laws and regulations. 3 Figure 26 FG020081 Inspection, Maintenance and Adjustment 4-29 DX225LC-3