Doosan DX225LC-3 — Clean Outer Filter of Air Cleaner

Clean Outer Filter of Air Cleaner NOTE: Clean outer filter every 500 hours/3 months of service. AM H H NOTE: If air cleaner clogged warning symbol (Figure 64) on display monitor comes "ON", the air cleaner must be serviced. E F C C rpm NOTE: When working in very dusty conditions, the service interval must be shortened. FG018716 s DIG ISO USB Min Max WARNING Figure 64 AVOID DEATH OR SERIOUS INJURY Never clean or attempt to remove air cleaner filter if the engine is running. If using compressed air to clean the filter, make sure that proper eye protection is worn. 1. Locate the air cleaner assembly. NOTE:

When it reaches every 500 hours or If indicator symbol (Figure 64) on display monitor comes "ON" the air cleaner must be serviced. NOTE: Replace outer filter after cleaning 5 times or every 2,000 hours/1 year of service. 2. Remove and clean rubber evacuator valve (1, Figure 65) from bottom of air cleaner housing cover (2). Inspect seal lips for wear or damage. Replace valve if necessary. NOTE: Install evacuator valve with lips parallel to the cover. Figure 65 3. Remove access cover (2, Figure 66) by loosening the latches (3). 4. Remove outer filter (4, Figure 66) from the housing. Do not remove inner filter (5).

5 4 2 1 3 Figure 66 FG018333 Inspection, Maintenance and Adjustment 4-51 DX225LC-3 2 1 FG019434