Doosan DX225LC-3 — Change Oil in Travel Reduction Device (One on Each Side of Unit)

Change Oil in Travel Reduction Device (One on Each Side of Unit) 3 WARNING 1 The gear oil is very hot after the machine has been operating. Shut all systems down and allow them to cool. AVOID DEATH OR SERIOUS INJURY 2 EX1300564 Before removing the motor case, loosen the plug slightly to allow pressurized air to escape. Residual pressure in the travel reduction device can cause the plug to be dislodged and oil to squirt out suddenly. Figure 88 NOTE: Drain oil after first 500 hours of operation or rebuild, and every 1,000 hours thereafter. 1. Make sure that the machine is on firm and level ground. 2. Rotate the track until ports (1 thru 3, Figure 88) are in their proper positions as shown. 3.

Place a container under drain plug (2, Figure 88) and remove plugs (1 thru 3) to drain the travel reduction gear oil. NOTE: Dispose of drained fluids in compliance with all applicable environmental regulations. 4. Install drain plug (2, Figure 88). Refill the travel reduction gear case with fluid through fill port (3) until fluid level is at port (1). Install level plug (1) and fill plug (3). NOTE: See “Fluid Capacities” on page 4-18. for capacity. 5. Repeat this procedure on the other travel reduction device. DX225LC-3 Inspection, Maintenance and Adjustment 4-60 Reference Number Description 1 Oil Level Plug 2 Drain Plug 3 Fill Plug