Komatsu — PRECAUTIONS WHEN HANDLING AUTO-GREASING SYSTEM

. ATTACHMENTS, OPTIONS HANDLING AUTO-GREASING SYSTEM METHOD OF OPERATING AUTO-GREASING SYSTEM is turned ON, this 2. Auto-greasing switch (1) PRECAUTIONS WHEN HANDLING AUTO-GREASING SYSTEM Loosen lock nut (2) and turn adjustment screw (3) counterclockwise. 3. Method of bleeding air from main line 6 - 4 1. When the starting s witch of the machin system automaticall If auto-greasing swit ch (1) is pressed, the greas e pump c an be operated, regardless of the timer. The grease p ump op erates only while the auto -greasing switch is pressed . The grease pump stops auto-greasing switch is released. This switch is used m ainly to check the operatio n of the g rease pump or to supply a 1.

Lower the bucket ho rizontally to the ground 2. Adjustment of discha rge from injector (1) Set the all injectors t o the maximum discharge. Loosen the plug inst alled to each injector to bleed air from the main piping. This wo rk shall be carry out b y two persons . Start bleeding at the inject or nearest the grease pump , then bl eed at the other injectors in order (Rear frame -> Front f rame -> Boom -> Bell crank).