Detroit Diesel — Marine Controls Data List

Appendix A • Parameter Listings 196 Detroit Diesel Application User’s Manual Parameter Range Description GEAR RATIO SET YES or NO Indicates that a new gear actuator ratio has been calculated. Only avail- able for version 2.0 and 2.5 marine controls. GEAR RATIO 0-999.9 Indicates the gear ratio. Only avail- able for version 2.0 and 2.5 marine controls. HRS IN SERV 0-99999 Indicates the total hours the ERIM has been in service with either ignition switch. #LVR C/HEADS DUAL or SINGLE Indicates whether dual control head levers are used at the active station. MASTER THROT PORT/STBD Indicates which throttle lever (either Port or Starboard) is master in sync mode.

NON VOL MEM OK or BAD Indicates whether the non-volatile memory is defective. PORT ENGINE RPM 0-3000 Indicates the engine RPM as seen by the Port ECM. PORT TO ECM RPM 0-2040 Indicates the requested RPM from the ERIM to the Port ECM. STBD ENGINE RPM 0-3000 Indicates the engine RPM as seen by the Starboard ECM. STBD TO ECM RPM 0-2040 Indicates the requested RPM from the ERIM to the Starboard ECM. PORT IDLE RPM 0-999 Indicates the current RPM value the Port ECM is using to maintain idle speed. STBD IDLE RPM 0-999 Indicates the current RPM value the Starboard ECM is using to maintain idle speed. PORT COMMAND RPM 0-2040 Indicates the requested Port Engine RPM from the CSIM to the ERIM.

STBD COMMAND RPM 0-2040 Indicates the requested Starboard Engine RPM from the CSIM to the ERIM.