Detroit Diesel — Marine Controls Data List

DDEC Marine Controls Parameters Detroit Diesel Application User’s Manual 197 Parameter Range Description PT GEAR ACT POS REV, NEUT, FWD, UNKN Indicates the current position in per- centage of full travel of the Port Gear actuator. Only available for version 3.0 marine controls. PT GEAR ACT CMD NEUT, FWD, REV Indicates the gear currently being commanded by the ERIM to the Port Gear actuator. PT GEAR ACT REQ NEUT, FWD, REV Indicates the gear currently being selected by the Port control head through CSIM. ST GEAR ACT POS REV, NEUT, FWD, UNKN Indicates the current position in per- centage of full travel of the Starboard gear actuator.

Only available for version 3.0 ST GEAR ACT CMD NEUT, FWD, REV Indicates the gear currently being commanded by the ERIM to the Star- board gear actuator. ST GEAR ACT REQ NEUT, FWD, REV Indicates the gear currently being selected by the Starboard Control head through CSIM. PORT SOL ENG YES or NO Indicates whether the Port engine solenoid is engaged. Only available for version 2.0 and 2.5 marine controls. STBD SOL ENG YES or NO Indicates whether the Starboard engine solenoid is engaged. Only available for version 2.0 and 2.5 marine controls. PORT NEUT STAT YES or NO Indicates that the Port marine gear actuator is in the neutral position. Only available for version 2.0 and 2.5 marine controls.

STBD NEUT STAT YES or NO Indicates that the Starboard marine gear actuator is in neutral position. Only available for version 2.0 and 2.5 marine controls. PORT ENG RUN YES or NO Indicates whether the Port engine is running.