UEN00100-00 10 Structure, function and maintenance standard 2. When the arm is in neutral Operation q Returning the lever to neutral reduces the pilot pressure from the PPC valve to 0 kg/cm 2 . q The pressurized oil that has flowed and been drained through orifice (a) in valve (2) is closed by pilot piston (1). q The holding pressure on the arm bottom side works on the difference between areas (S2) and (S1) of valve (2) to the left. q Valve (2) is closed by the total of this force and the force of spring (3), so ports (A) and (B) are shut off. 52 PC210, 230, 240-8