Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Hydraulic drift prevention valve

10 Structure, function and maintenance standard UEN00100-00 Lift check valve 1 Function q This valve applies back pressure to the drain circuit to prevent generation of negative pres- sure on each actuator (motors, cylinders, etc.). 2. While engine is running q Output pressure (PR) of the self pressure reducing valve is applied via the control valve to spring chamber (c) of back pressure valve (3). Operation q Output pressure (PR) applied to spring cham- ber (c) is applied to the left end of valve (1) (area of φ d) to push valve (1) to the right. 1.

While engine is stopped q Pressurized oil is not fed to the self pressure reducing valve from the pump, and valve (1) is pressed to the right by the force of spring (2). q At this time, pressure (PA) of drain circuit (a) of the control valve is applied to the right end of valve (1) (area of φ d1) to push valve (1) to the left. q Drain circuit (a) of the control valve is con- nected with port (T) through orifice (b) of valve (1). q Valve (1) strikes balance to make the back pressure equal to (PA) in the equation below. PA= (Area of fd) x PR + force of spring (2) Area of φ d1 PC210, 230, 240-8 53