30 Testing and adjusting UEN00228-00 Measuring control circuit basic pressure 1 3. Start the engine, set the working mode in the power mode (P), and turn the auto-decelerator OFF. a Measuring tools for control circuit basic pres- sure 4. Run the engine at high idle, set all the levers and pedals for work equipment control, swing control, and travel in neutral, and measure the oil pressure. k Stop the machine on a level ground and lower the work equipment to the ground. Then, release the residual pressure from the hydraulic circuit. For details, see “Releasing residual pressure from hydrau- lic circuit”. a Measure the control circuit basic pressure under the following condition.
q Hydraulic oil temperature: Within operating range 1. Remove the control valve top cover and oil pressure pickup plug (1). 5. After finishing measurement, remove the mea- suring tools and return the removed parts. a The control circuit basic pressure may be mea- sured with oil pressure pickup plug (2) on the hydraulic pump side. 2. Install nipple K2 and connect oil pressure gauge [1] of hydraulic tester K1 . a Use the oil pressure gauge of 5.9 MPa {60 kg/cm 2 }. PC240-8 a Do not adjust the relief valve for control circuit basic pressure. PC210, 230, 240-8 31 Symbol Part No.
Part name K 1 799-101-5002 Hydraulic tester 790-261-1204 Digital hydraulic tester 2 799-101-5220 Nipple (10 × 1.25 mm) 07002-11023 O-ring PC21 2 0/230-8