UEN00228-00 30 Testing and adjusting Measuring and adjusting oil pressure in pump PC control circuit 1 a Measuring and adjusting tools for oil pressure in pump PC control circuit k Stop the machine on a level ground and lower the work equipment to the ground. Then, release the residual pressure from the hydraulic circuit. For details, see “Releasing residual pressure from hydrau- lic circuit”. PC240-8 Measuring a Before measuring the oil pressure in the PC control circuit, check that the oil pressure in the work equipment, swing, and travel circuits and the basic pressure of the control circuit are nor- mal.
a Measure the oil pressure in the pump PC con- trol circuit under the following condition. 2) Install nipples L2 and nipples [1] of hydraulic tester L1 and connect them to oil pressure gauges [2]. a Connect the measuring part of plug (3) by using joint (790-301-1271) and elbow (790-301-1530) of hydraulic tester L1 and nipple [1] so that it will not interfere with the drain piping. a Use the oil pressure gauges of 58.8 MPa {600 kg/cm 2 }. q Hydraulic oil temperature: Within operating range 1. Measuring PC valve output pressure (servo piston inlet pressure) a Measure the PC valve output pressure (servo piston inlet pressure) and pump discharge pressure simultaneously and compare them.
1) Open the side cover of the pump room and remove oil pressure pickup plugs (1), (2), (3), and (4). q (1): Front pump discharge pressure pickup plug q (2): Rear pump discharge pressure pickup plug q (3): Front PC valve output pressure pickup plug q (4): Rear PC valve output pressure pickup plug 32 PC210, 230, 240-8 PC2 4 10/230-8 2 1 Warning:Test points revers on PC210/230-8 pump 3 ed Symbol Part No. Part name L 1 799-101-5002 Hydraulic tester 790-261-1204 Digital hydraulic tester 2 799-101-5220 Nipple (10 × 1.25 mm) 07002-11023 O-ring PC21 L2 L2 0/230-8 L2 1