30 Testing and adjusting UEN00228-00 1. Loosen locknut (9). a Before loosening the locknut, make counter mark at the adjustment screw end so that you can see the position of the locknut before the adjustment (and you can return the locknut to its original posi- tion after turning it in reverse). 2. Turn adjustment screw (10) clockwise or coun- terclockwise to adjust. a Turn the adjustment screw q Clockwise when the work equipment speed is low (to increase pump absorption torque) and q Counterclockwise when the engine speed lowers (to decrease pump absorption torque). 3. Tighten locknut (9). 3 Locknut: 27 – 34 Nm {2.8 – 3.5 kgm} 4.
After finishing adjustment, check again that the PC valve output pressure (servo piston inlet pressure) is normal according to the above described measurement procedure. PC210, 230, 240-8 35