UEN00228-00 30 Testing and adjusting Checking parts which cause hydraulic drift of work equipment 1 2. Checking arm cylinder 1) Stop the arm cylinder about 100 mm before the IN stroke end and stop the engine. a If the work equipment (cylinder) drifts hydrauli- cally, check to see if the cause is on the cylin- der packing side or control valve side according to the following procedure. 1. Checking boom cylinder and bucket cylinder 1) Set the machine in the position for mea- suring hydraulic drift and stop the engine. a Fill the bucket with a rated load or with dirt and sand. 2) Operate the arm control lever in the IN position.
q If the lowering speed is increased at this time, the cylinder packing is defective. q If the lowering speed does not change at this time, the control valve is defec- tive. a Operate the control lever while the starting switch is in the ON position. a If the pressure in the accumulator is lost, run the engine for about 5 sec- onds to heighten the pressure in the accumulator. [ Reference ] Reason why the lowering speed is increased by the above operation when the cylinder packing is the cause of the hydraulic drift: 1) If the machine is set in the above position (where the holding pressure is applied to the bottom side), the oil leaks from the bottom side to the head side.
Since the volume on the head side is less than that on the bottom side by the volume of the rod, the pressure in the head side is increased by the oil flowing in from the bottom side. 2) As the pressure in the head side is increased, it is balanced at a certain level (which depends on the leakage), and then the lowering speed is lowered. 3) If the circuit on the head side is opened to the drain circuit by the above operation of the lever (the bottom side is closed by the check valve at this time), the oil on the head side flows in the drain circuit. As a result, the pressure is unbalanced and the lowering speed is increased.
2) When checking the boom cylinder, set the boom control lever in the RAISE position. When checking the bucket cylinder, set the bucket control lever in the CURL position. q If the lowering speed is increased at this time, the cylinder packing is defective. q If the lowering speed does not change at this time, the control valve is defective. a Operate the control lever while the starting switch is in the ON position. a If the pressure in the accumulator is lost, run the engine for about 5 sec- onds to heighten the pressure in the accumulator. 48 PC210, 230, 240-8