UEN00228-00 30 Testing and adjusting Releasing residual pressure from hydraulic circuit 1 4) Repeat steps 2) and 3) above 2 – 3 times, and the residual pressure in the piping is released completely. 1. Releasing residual pressure from hydraulic tank k Since the hydraulic tank is enclosed and pressurized, release the residual pressure from it when removing a hose or a plug connected to it. 1) Lower the work equipment to the ground in a stable position and stop the engine. 2) Loosen oil filler cap (1) of the hydraulic tank gradually to release the air in the tank. 3.
Releasing residual pressure from swing motor circuit The residual pressure in the swing motor cir- cuit can be released by performing the opera- tion for “Releasing residual pressure from hydraulic cylinder circuit” (Operate the lever in the swing direction only, however). 4. Releasing residual pressure from travel motor circuit Since the control valve spool of the travel motor circuit is open, the pressure in this circuit can be released by performing “Releasing residual pressure from hydraulic tank”. 2.
Releasing residual pressure from hydraulic cylinder circuit k When disconnecting a pipe between a hydraulic cylinder and the control valve, release the residual pressure from the piping according to the follow- ing procedure. 1) Lower the work equipment and release the residual pressure from the hydraulic tank. For details, see “Releasing residual pres- sure from hydraulic tank”. a Keep the oil filler cap of the hydraulic tank removed. 2) Turn the starting switch ON and set the lock lever in the FREE position, and then operate the right and left work equipment control levers forward, backward, to the right, and to the left. a The control valve is operated by the pressure in the accumulator.
The pressure in the accumulator is used up, however, after the control valve is operated 2 – 3 times. 3) Run the engine at low idle for 5 seconds to heighten the pressure in the accumulator. a The engine does not start until the lock lever is set in the LOCK position once. 50 PC210, 230, 240-8