Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Bleeding air from each part

UEN00228-00 30 Testing and adjusting Bleeding air from each part 1 Note: Bleed air from the swing motor and travel motor only when the oil in the motor cases is drained. 1. Bleeding air from hydraulic pump 1) Loosen air bleeder (1) and check that oil oozes out through the air bleeder. 2) After the oil oozes out, tighten air bleeder (1). PC240-8 3 Air bleeder: 7.8 – 9.8 Nm {0.8 – 1.0 kgm} a Do not use an impact wrench to tighten the air bleeder.

54 PC210, 230, 240-8 Air bleeding item Contents of work Air bleeding procedure 1 2 3 4 5 6 Bleeding air from hydraulic pump Starting engine Bleeding air from cylinder Bleeding air from swing motor Bleeding air from travel motor Checking oil level and starting operation • Replacing hydraulic oil • Cleaning strainer q q q q (See note) q (See note) q • Replacing return filter element q o o o q • Replacing and repairing hydraulic pump • Removing suction piping q q q o o q • Replacing and repairing control valve • Removing control valve piping q q o o q • Replacing and repairing cylinder • Removing cylinder piping q q o o q • Replacing and repairing swing motor • Removing swing motor piping q o q o q • Replacing and repairing travel motor • Removing travel motor piping q o o q q • Replacing and repairing swivel joint • Removing swivel joint piping q o o o q PC210/230-8 1