30 Testing and adjusting UEN00228-00 2. Starting engine When running the engine after performing step 1, keep its speed at low idle for 10 minutes. a If the engine coolant temperature is low and the automatic warm-up operation is started, stop the engine temporarily and reset the automatic warm-up operation with the fuel control dial (Set the starting switch in the ON position and hold the fuel control dial in the MAX position for 3 sec- onds, and the automatic warm-up opera- tion is reset). 3. Bleeding air from cylinder a If a cylinder is replaced, bleed air from it before connecting the work equipment.
In particular, the boom cylinder does not move to the lowering stroke end, if it is installed to the work equipment. 1) Run the engine at low idle for about 5 min- utes. 2) While running the engine at low idle, raise and lower the boom 4 – 5 times. a Stop the piston rod about 100 mm before each stroke end. Do not relieve the oil. PC210, 230, 240-8 55