30 Testing and adjusting UEN00229-00 Function of checking display of LCD (Liquid Crystal Display) While the ordinary screen is displayed, if the follow- ing numeral input switch and function switch are operated as follows, all the LCD (Liquid Crystal Dis- play) lights up in white. Function of checking service meter To check the service meter while the starting switch is turned OFF, operate the numeral input switches as follows. At this time, only the service meter sec- tion displays. q Operation of switches (simultaneous): [4] + [1] a Since there is some time lag in start of the LCD, hold down the switches until the LCD dis- plays normally.
a After the machine monitor is used continu- ously, blue points (points which do not go off) may be seen on this screen. This phenomenon does not indicate a failure or a defect. q Operation of switches (simultaneous): [4] + [F2] a When finishing the operation of the switches, release [F2] first. a If there is a display error in the LCD, only that part is indicated in black. a The LCD panel sometimes has black points (points which are not lighted) and bright points (points which do not go off) for the reason of its characteristics. If the number of the bright points and black points does not exceed 10, those points are not a failure or a defect.
a To return to the former screen, press the func- tion switch. PC210, 230, 240-8 17