UEN00230-00 30 Testing and adjusting 3. Pump controller 1) Slide the operator's seat and seat stand to the forward end. 2) Remove the 5 mounting bolts and cool & hot box (6). a While removing the cool & hot box, disconnect the drain hose. 3) Remove the 2 mounting bolts, 1 fastener, and magazine box (7). 4) Remove the 3 mounting bolts and cover (8). 5) Remove fuse box cover (9) and cover (10). a Since the underside of cover (10) is clamped, pull it up. 6) Remove the 7 mounting bolts and cover (11). a The connectors of the pump control- ler have a special locking mecha- nism. Disconnect them according to steps (a) – (c) and connect them according to steps (d) – (f) as shown below.
Disconnection : (a) Unlock – (b) Slide lever – (c) Disconnect connec- tor. Connection : (d) Position connector – (e) Slide lever – (f) Lock. 4. KOMTRAX communication module 1) Slide the operator's seat and seat stand to the forward end. 2) Remove the 5 mounting bolts and cool & hot box (6). a While removing the cool & hot box, disconnect the drain hose. 3) Remove the 2 mounting bolts, 1 fastener, and magazine box (7). 4) Remove the 3 mounting bolts and cover (8). 5) Remove fuse box cover (9) and cover (10). a Since the underside of cover (10) is clamped, pull it up. 6) Remove the 7 mounting bolts and cover (11).
7) Connect the troubleshooting adapters to connectors C01 and C02 of pump control- ler (12). a Install the adapters to only the wiring harness side. 4 PC210, 230, 240-8