40 Troubleshooting UEN00244-00 E-3 Engine does not start (Engine does not turn) 1 PC210, 230, 240-8 11 Trouble • Engine does not start (Engine does not turn). Related infor- mation • Engine starting circuit has following 2 start lock mechanisms. 1) Start lock with password of machine monitor 2) Start lock with lock lever Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Low charge level of battery a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Battery voltage (2 pieces) Electrolyte specific gravity (1 piece) Min. 24 V Min. 1.26 2 Defective fuse No.
3 If fuse is broken, circuit probably has ground fault. (See cause 10.) 3 Defective starting switch (Internal disconnection) a Prepare with starting switch OFF, then keep starting switch OFF and turn it to START and carry out troubleshooting in each case. H15 (male) Starting switch Resistance Between (1) – (4) OFF Min. 1 Mz START Max. 1 z 4 Defective lock lever switch (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. S14 (female) Lock lever Resistance Between (1) – (3) Free Min. 1 Mz Lock Max.
1 z 5 Defective starting motor cut- out relay R06 or R07 (Inter- nal disconnection or short circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. R06 (male), R07 (male) Resistance Between (1) – (2) 300 – 600 z Between (3) – (4) Max. 1 z Between (3) – (5) Min. 1 Mz 6 Defective starting motor safety relay (Internal defect) a Prepare with starting switch OFF (with only terminal C discon- nected), then turn starting switch to START and carry out trou- bleshooting. Safety relay terminal Voltage Between B – E Power supply 20 – 30 V Between R (R17-2) – E Generation input Max.
1 V Between S (R17-1) – E Starting input 20 – 30 V Between C (R18) – E Starting output 20 – 30 V If power supply, generation input, and starting input are normal but starting output is not normal, starting motor safety relay is defective.