50 Disassembly and assembly UEN00660-00 2. Vibration damper 1) Install vibration damper (13), aligning its dowel hole with dowel pin a of the crank- shaft. 2) Tightening procedure of bolts (15) 1] Tighten to a torque of 55 ± 5 Nm {5.6 ± 0.5 kgm} in diagonal order. 2] Loosen the bolts 180°. 3] Tighten to a torque of 55 ± 5 Nm {5.6 ± 0.5 kgm} in diagonal order. 4] 90° ± 5° a Tool A6 : wrench is adopted for angle tightening. (Refer to the tool list.) (Refer to the tool list.) q When an angle tightening tool is not used: Put marks on the vibration damper and bolts with a felt-tip pen, and then tighten the bolts an additional 90° ± 5° .
q Carry out the rest of installation in the reverse order to removal. [*1] 3 Fan mounting bolt: 43 ± 6 Nm {4.4 ± 0.6 kgm} [*2] a Refer to the Inspection and Adjustment of Air Compressor Belt Tension section in the Testing and adjusting chapter in this manual. PC210, 230, 240-8 13