OPERATION 3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS Fault No. 854: (857) $h: PTO-gear 1 oil filter restricted Help: - Replace filter element. (indicated by B27-1) Fault No. 860: (863) $h: Pump regulation 1 oil filter restricted Help: - Replace filter element. (indicated by B22-1) Fault No. 866: (869) $h: Oil tank breather filter restricted Help: - Replace filter element. (indicated by B24) Fault No. 872: (875) $h: Return oil filter restricted Help: - Replace filter elements. (indicated by B26) Fault No. 878: (881) $h: Leak oil filter restricted Help: - Replace filter element. (indicated by B25) Fault No. 884: (887) $h: Faulty monitor channel for charge- /discharge cur- rent. Help:
The monitor channel for charge-/discharge current shows inadmissible values. - Check frequency converter E7 and shunt R3. Fault No. 890: (893) $h: Fan drive oil filter oil cooler 1 restricted Help: - Replace filter element. (indicated by B28-1) Fault No. 896: (899) $h: Battery charging circuit failure Help: The ECS detects a battery charging current with the machine turned off. - Check battery charging circuit for separate feeding. 183