3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS OPERATION Fault No. 902: (905) $h: Load of the batteries too high Help: Too much current is being taken from the batteries. - Check board net for short circuit. - Switch off unnecessary consumers. Fault No. 908: (911) $h: Batteries are not being charged Help: - Check charging circuit for broken cables. - Switch off unnecessary consumers. Fault No. 914: (917) $h: Battery charging current too high Help: - Check boardnet for short circuit. - Check generator and batteries. Fault No. 920: (923) $h: Faulty monitor channel for oil temperature of PTO gear 2 Help: Temperature sensor B49-2 for PTO gear oil shows inad- missible values.
- Check sensor and cables. Fault No. 926: (929) $h: Oil temperature of PTO gear 2 too high Help: - Check gear oil cooling circuit. - Clean gear oil cooler. (indicated by B49-2) Fault No. 932: (935) $h: Faulty monitor channel for fuel level Help: Pressure transducer B63 for fuel level shows inadmissible values. - Check monitor channel and transducer. Fault No. 938: (941) $h: Hydraulic oil temperature too high. Bucket motion switched off. Help: Cool off the oil by moving attachment w/o load. - Check hydraulic oil cooling system. - Clean oil cooler. 184