OPERATION 3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS Fault No. 944: (947) $h: Faulty monitor channel for oil temperature of PTO gear 1 Help: Temperature sensor B49-1 for PTO gear oil shows inad- missible values. - Check sensor and cables. Fault No. 950: (953) $h: Oil temperature of PTO gear 1 too high Help: - Check gear oil cooling circuit. - Clean gear oil cooler. (indicated by B49-1) Fault No. 956: (959) $h: Faulty monitor channel for ambient temperature Help: Temperature sensor B90 for ambient temperature shows inadmissible values. - Check sensor and cables. Fault No. 962: (965) $h: Control pressure X1-1 for the main pumps too high Help: - Check / adjust electronic pump regulation.
- Check / adjust pressure reduction valve. (indicated by B85-1) Fault No. 968: (971) $h: Pilot pressure X2 too low. Help: - Check / adjust pressure relief valve. (indicated by B86) Fault No. 974: (977) $h: Pilot pressure X2 too high Help: - Check / adjust pressure relief valve. (indicated by B86) Fault No. 980: (983) $h: Swing gear house brake OFF Help: - Check solenoid valve Y5. - Check pressure switch B16. Fault No. 986 (989) $h: Travel gear house brake OFF Help: - Check solenoid valve Y16. - Check pressure switch B48. 185