Komatsu — 3.4.6 FAULT AND INFORMATION MESSAGE LIST

3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS OPERATION Fault No. 992: (995) $h: Travel gear house brake ON Help: - Check solenoid valve Y16. - Check pressure switch B48. Fault No. 998: (1001) $h: Faulty monitor channel for onboard mains tension Help: The mains tension is beyond the permissible limits. - Check monitor channel. Fault No. 1004: (1007) $h: Board net voltage too high Help: - Check generator and regulator. Fault No. 1010: (1013) $h: Board net voltage too low Help: - Check batteries - Check generator. Fault No. 1016: (1019) $h: Faulty monitor channel for X1-2-pressure Help: Pressure pick up B85-2 for the X1-2-pressure shows inad- missible values. - Check sensor and cables.

Fault No. 1022: (1025) $h: Control pressure X1-2 for the main pumps too high Help: - Check / adjust electronic pump regulation. - Check / adjust pressure reduction valve. (indicated by B85-2) Fault No. 1028: (1031) $h: Central lube system grease container empty Help: The message sensor B108 grease container empty has responded. - Replace or fill grease container. 186