Komatsu — METHOD FOR RELEASING INTERNAL PRESSURE IN HYDRAULIC CIRCUIT

. MAINTENANCE MAINTENANCE PROCEDURE METHOD FOR RELEASING INTERNAL PRESSURE IN HYDRAULIC CIRCUIT WARNING 4 - 42 Th e hydraulic system is always und er internal pressure, so wh en inspecting or replacing the pipi ng or hoses, always re lease th e pressure in the circu it before st arting. If t he pressure is no t released, high pressure oil may s purt out and cause s erious persona l inju Th e par ts and oil are at h igh temperature after the engine is st opped, and may cause serious bur ns. Wait for the temperature to go do wn b efore starti ng the operation. When th e oil filler cap is removed, o il may spurt out, so t urn th e cap slowly to release the pressu re before removing th e cap. 1.

S top t he m achine on firm level ground. 2. T urn t he s tarting sw itch to ON position (B ) within 15 s econds a F e p fter stopping the machine. Then set th e leve r to the r (work the REE position (F) and operate eac h c leve quipment , travel) fu lly in each direction to releas e the internal ressure.