Kubota — SERVICING

03-M-E3B, 03-M-DI-E3B, 03-M-E3BG WSM DIESEL ENGINE CAUTION Check the injection pressure and condition after confirming that there is nobody standing in the direction the fume goes. If the fume from the nozzle directly contacts the human body, cells may be destroyed and blood poisoning may be caused. Nozzle Spraying Condition [D1503-M, D1703-M, D1803-M, V2003-M, V2203-M, V2403-M, V2403-M-T] [D1703-M-BG, V2003-M-BG, V2003-M-T-BG, V2203-M-BG, V2403-M-BG] 1. Set the injection nozzle to a nozzle tester, and check the nozzle spraying condition. 2. If the spraying condition is defective, replace the nozzle piece. (a) Good (b) Bad [D1803-M-DI, V2403-M-DI, V2403-M-DI-T] 1.

Set the injection nozzle to a nozzle tester, and check the nozzle spraying condition. 2. If the spraying condition is defective, replace the injection nozzle assembly. W10181310 (a) Good (b) Bad W10226470 S-33 KiSC issued 07, 2008 A