MAN Nutzfahrzeuge Aktiengesellschaft — Repairing coolant pump with high-temperature and low-temperature parts

Repairing coolant pump with high-temperature and low-temperature parts Fig. 12 Note: Brace the bearing shaft. Press impeller slowly on to bearing shaft (mandrel 80.99604−0252) to ensure that the correct gap (0,5 +0,4 ) is achieved. 12 Fig. 13 Press axial−face seal (no. 8) into pump housing (no. 1) using pressing tool (80.99606−0252). Observe installation note for seal on page 60. 13 Fig. 14 Lay coolant pump gasket on pump housing. 14 Fig. 15 Carefully fit low-temperature suction part to high- temperature pump housing. To make assembly easier insert 2 pins in opposite sides of HT part (see Fig. 14) Do not use force (hammer etc.) and note the 3 centring features (see arrows in Fig. 14).

Screw in bolt (Fig. 1, item 5). Bolt LT and HT parts together with 2 bolts and nuts on opposite sides (Fig. 1, item 4). 15 57