TESTING AND ADJUSTING STANDARD VALUE TABLE FOR ELECTRICAL PARTS 20-15 Sys- tem Name of component Connector No. Inspec- tion method Judgement table Measurement conditions Control system Engine shrottle, pump controller Swing holding brake solenoid C01 Measure voltage If the condition is as shown in the table below, it is normal When swing lever is operated (solenoid 20 - 30 V ON, swing holding brake canceled) After approx. 5 Between seconds have (3) - (6), (12) passed since returning swing lever 0 - 3 V to neutral (solenoid OFF, swing holding brake operated) 1) Start engine. 2) Turn swing lock switch OFF. 3) Turn swing lock prolix switch OFF. 4) Insert T-adapter.
Travel speed solenoid C01 Measure voltage If the condition is as shown in the table below, it is normal When traveling with travel speed switch at Hi (solenoid OFF, 0 - 3 V travel motor swash plate angle at MIN) Between When traveling with (9) - (6), (12) travel speed switch at Lo, Mi (solenoid 20 - 30 V ON, travel motor swash plate angle at MAX) 1) Start engine. 2) Insert T-adapter. 3) Turn fuel control dial to MAX position. 4) Travel on level ground. 2-stage relief solenoid C01 Measure voltage If the condition is as shown in the table below, it is normal Work equipment control lever operated + power max.
switch ON 20 - 30 V (solenoid ON, 2- Between stage relief actu- (10) - (6), ated) (12) All levers at neutral (solenoid OFF, 0 - 3 V 2-stage relief canceled) 1) Start engine. 2) Insert T-adapter. When swing lever is operated (solenoid ON, swing holding brake canceled) Between (3) - (6), (12) 20 - 30 V After approx.
5 seconds have passed since returning swing lever to neutral (solenoid OFF, swing holding brake operated) 0 - 3 V When traveling with travel speed switch at Hi (solenoid OFF, travel motor swash plate angle at MIN) Between (9) - (6), (12) 0 - 3 V When traveling with travel speed switch at Lo, Mi (solenoid ON, travel motor swash plate angle at MAX) 20 - 30 V Work equipment control lever operated + power max. switch ON (solenoid ON, 2- stage relief actu- ated) Between (10) - (6), (12) 20 - 30 V All levers at neutral (solenoid OFF, 2-stage relief canceled) 0 - 3 V