Komatsu — STANDARD VALUE TABLE FOR ELECTRICAL PARTS

TESTING AND ADJUSTING STANDARD VALUE TABLE FOR ELECTRICAL PARTS Sys- tem Measurement conditions 1) Start engine. 2) Set monitoring code to 16 (command value). 3) Operate working mode switch and L.H. knob switch. Control system 1) Turn starting switch OFF. 2) Disconnect connector. 3) Connect T-adapter to wiring harness end. 20-17 Name of component Connector No. Inspec- tion method Judgement table Engine throttle, pump controller No.2 throttle signal Monitoring code 16 If the condition is as shown in the table below, it is normal High idling (rpm) H/O Approx. 2100 G/O Approx. 1950 F/O Approx. 1950 L/O Approx. 1600 H/O + Power max. Approx. 2100 Swift slow-down Approx.

1600 Model selection C17 - C02 Continuity If the condition is as shown in the table below, it is normal Model selection 1 C17 (5) - C02 (11) No continuity Model selection 2 C17 (13) - C02 (11) No continuity Model selection 3 C17 (6) - C02 (11) No continuity Model selection 4 C17 (14) - C02 (11) No continuity Model selection 5 C17 (7) - C02 (11) No continuity H/O Approx. 2100 G/O Approx. 1950 F/O Approx. 1950 L/O Approx. 1600 H/O + Power max. Approx. 2100 Swift slow-down Approx.

1600 Model selection 1 C17 (5) - C02 (11) No continuity Model selection 2 C17 (13) - C02 (11) No continuity Model selection 3 C17 (6) - C02 (11) No continuity Model selection 4 C17 (14) - C02 (11) No continuity Model selection 5 C17 (7) - C02 (11) No continuity