Komatsu — METHOD OF USING JUDGEMENT TABLE

TROUBLESHOOTING TESTING AND ADJUSTING METHOD OF USING JUDGEMENT TABLE 2. When using judgement table for engine throttle - pump controller (governor control system) and hydraulic related parts If a service code is displayed on the monitor panel, go to the troubleshooting code at the bottom of the judgement table (C- ). (A mark is put at the places where the failure mode and service code match.) If a problem has appeared but no service code is displayed on the monitor panel, go to the point where the failure mode matches the input signal, and check the display for the input signal (the display at the place with a O mark).

If it is displayed normally, go to the troubleshooting code on the right of the judgement table (H- ). If the input signal is not displayed on the monitor panel, go to the troubleshooting code at the bottom of the judgement table (F- ). Failure mode "Upper structure does not swing". Procedure: Check if the service code is being displayed on the monitor panel. JUDGEMENT TABLE FOR PUMP CONTROLLER AND HYDRAULIC RELATED PARTS [Judgment] 1) If a service code is being displayed on the monitor panel .... go to troubleshooting [E2: ) for the engine throttle - pump controller (pump control system). 2) If no service code is displayed on the monitor panel, and the upper structure does not swing:

There is a signal ........Go to troubleshooting H-25 of mechanical system Check engine throttle - pump controller input signal (Check in monitoring mode) There is no signal ......Go to troubleshooting F- of engine throttle - pump controller input signal system (F mode for applicable system) 20-94