TROUBLESHOOTING E-4 E-4 [318] Abnormality (short circuit) in motor drive system is displayed # This troubleshooting is carried out when there is still an abnormality, so when disconnecting the connector and inserting the T-adapter, or when removing the T-adapter and returning the connector to its original position, if the service code E is not displayed, the problem has been removed. # If the abnormality occurs during operation, because of the force of the spring 1) the engine will run at low idling 2) the engine will not stop # If the problem occurs when the engine is stopped, 1) the engine can be started, but it stays in low idling, or 2) it will not stop after it is started.
Check with the engine stopped (push the fuel control lever of the fuel injection pump to the NO INJECTION position). # Before carrying out troubleshooting, check that all the related connectors are properly inserted. # Always connect any disconnected connectors before going on to the next step. Table 1 E-4 Related electric circuit diagram 20-119 2 YES Is resistance between YES each pin of C02 (female), or between 1 each pin and chassis Is resistance between as shown in Table 1? each pin of E05 • Turn starting switch NO (male), or between OFF. each pin and chassis • Disconnect C02. as shown in Table 1? • Turn starting switch OFF. NO • Disconnect E05.
Cause Remedy Defective governor, pump controller Defective wiring harness in system with defective resistance Defective governor motor Replace Replace Replace E05 (male) C02 (female Resistance value (1) - (2) (2) - (3) 2.5 - 7.5 kΩ (3) - (4) (4) - (5) 2.5 - 7.5 kΩ (1) - (3) (2) - (4) Min. 1 MΩ (1) - (4) (2) - (5) Min. 1 MΩ Between chassis and pins (1) (2) (3) (4) Between chassis and pins (2) (3) (4) (5) Min. 1 MΩ