Komatsu — C- 16 [ E226] Abnormality in pressure sensor power source system is displayed

TESTING AND ADJUSTING C-16 C-16 [E226] Abnormality in pressure sensor power source system is displayed # This troubleshooting is carried out when there is still an abnormality, so when disconnecting the connector and inserting the T-adapter, or when removing the T-adapter and returning the connector to its original position, if the service code "E" is not displayed, the problem has been removed. # If the starting switch is turned OFF after an abnormality occurs, turn the starting switch ON and check that the service code "E" is displayed. (If it is not displayed, the problem has been removed.) # Before carrying out troubleshooting, check that all the related connectors are properly inserted.

# Always connect any disconnected connectors before going on to the next step. 2 YES Defective pump pressure sensor (internal short circuit, short circuit with chassis ground) Replace YES 1 Is voltage between C03 (6) and (16) normal? Is resistance between C03 (female) (6) and (16), (6) (16) and chassis normal? Turn starting switch OFF Disconnect C03 and C08 Min. 1 M Ω Turn starting switch ON Disconnect C08 18 - 28 V NO Defective engine throttle, pump controller Replace NO Short circuit, short circuit with chassis ground between C03 (female) (6) and C08 (female) (2) Repair or replace C-16 Related electrical circuit diagram 20-191 Cause Remedy