TESTING AND ADJUSTING TROUBLESHOOTING M-13 f) (air cleaner clogging) flashes. # Check that the air cleaner is not clogged before carrying out troubleshooting. Defective air cleaner clogging sensor Replace YES 4 YES Does display go out when P11 (female) is connected to P12 (male)? 1 YES 3 Is bit (6) of monitoring code 24 lighted up? Defective governor, pump controller Replace Defective monitor panel Replace start engine YES Is continuity between C16 (female) (17) and chassis as shown in table? Start engine. Set to monitoring code 24.
NO Defective contact or disconnection in wiring harness between C16 (female) (17) and P11(female) Repair or replace Is there continuity between P12 (male) and chassis? 2 Turn starting switch OFF. Disconnect C16, P11 and P12. Connect disconnect P11 (female) to P12 (male). NO NO Turn starting switch OFF. Disconnect P12. Defective contact or disconnection in wiring harness between P12 (male) and chassis ground Repair or replace NO M-13 f) Related electric circuit diagram. 20-258 Cause Remedy