Komatsu — M- 16 Night lighting on monitor panel does not light up ( liquid crystal display is normal)

TESTING AND ADJUSTING TROUBLESHOOTING M-16 M-16 Night lighting on monitor panel does not light up (liquid crystal display is normal) # When the front lamp and working lamp light up normally. Blown bulb or defective contact of bulb Replace bulb, or clean (defec- tive contact) 1 YES Is bulb blown, or is there defective contact? 2 YES Defective monitor panel Replace Remove bulb. Check visually for blown bulb. Does bit (3) of monitoring code 49 go out? NO Is voltage between P01 (8) and (12) normal? 3 YES Turn starting switch ON. Set to monitoring code 49.

NO Defective contact, or disconnection in wiring harness between P01 (female) (8) - X01 (1) - M38 (female) (1) Repair or replace Turn starting switch ON. Turn light switch ON. 20-30V. NO M-16 Related electrical circuit diagram. 20-260 Cause Remedy