INSPECTION AND REPAIR 1 ENG 1"-1 4. Measure: ®~ ® @ 5 Minimum pump stroke ® Out of specification -+ Adjust. Minimum pump stroke ® : 0.15 .. 0.2 mm (0.0059 .. 0.0079 in) Measurement steps: • Turn the pump worm gearCDwith yourfinger, until the plunger top ® is at its maximum distance from the pump body mating surface @ ofthe pump cover. • Using a Feeler Gauge, measure the minimum pump stroke ® between the adjusting plate @ and the raised boss ® on the adjusting pul- ley. If minimum pump stroke is not within the specified limits, perform the adjustment steps. 5. Measure: Maximum pump stroke @ Out of specification -+ Adjust. Maximum pump stroke @ : 1.62 .. 1.8 mm (0.064 ..
0.071 in) Measurement steps: • Pull the oil pump cable CD out of its sheath as far as it will go. The cable must be held in this taut position when measuring the maximum pump stroke. NOTE: ______________________ _ It may be helpful to securely wrap duct tape ® around the cable where it enters the sheath. • Turn the pump worm gear @ with your fin- ger, until the plunger top @ is at its maximum distance from the pump body ® . • Using a Feeler Gauge, measurethe maximum pump stroke @ . • If maximum pump stroke is not within the specified limits, perform the adjustment steps. 5-13 http://ReadManuals.com