ELECTRICAL STARTING SYSTEM I ElECI iii I 5. Measure: • Mica CD (insulation depth) (between commutator segments) Out of specification -4 Scrape mica to proper limits. Use a hacksaw blade® that is ground to fit. Mica undercut @ : Limit: O.S mm (0.024 in) NOTE: ______________________ _ • The mica insulation of the commutator must be undercut to ensure proper operation of the commutator . • Carefully clean between the segments after the above steps. IAl CORRECT rnJ INCORRECT 6. Measure: , Armature coil resistance (insulation/continuity) Defect(s) -4 Replace starter motor. ~, :kj) ~~ " " nx 1 0 Inspecting steps:
• Connect the pocket tester (90890-03112, YU-03112) for continuity check CDand insula- tion check ® . • Measure the armature coil resistances. ~ Armature coil resistance: Continuity check CD : 0.01S0 ± S% at 20·C (S8·F) Insulation check ® : More than 100 KQ at 20· C (S8·F) If the resistance is incorrect, replace the starter motor. 7. Measure: • Brush length ® Out of specification -4 Replace. Brush length limit ® : 8.5 mm (0.33 in) 8-12 http://ReadManuals.com