Engines and Clutches 6. C-10, C-12, and C-15 engines may be operated at low load and speed once the engine oil pres- sure has reached 10 to 20 psi (69 to 138 kPa). When the engine has reached the normal operat- ing temperature of 189°F (87°C), the engine may be operated at full load main engine electrical harness on the left frame rail, near the batteries. If needed, replace the fuses. Be sure to find the cause of the blown fuses as soon as possible. NOTE: Some starters are equipped with an op- tional thermostat. If overcranking occurs, the thermostat breaks the electrical current to the starter motor until the motor has cooled. Cummins and Detroit Diesel NOTE:
Before starting the engine, read Chap- ter 2 in this manual for detailed information on how to read the instruments and operate the controls. On vehicles equipped with a neutral start switch, the transmission must be in neutral before the engine can be started. 6. Press the start button. Release the button the moment the engine starts. If the vehicle is equipped with an automatic en- gine shutdown system with a manual override push button, press the override button while pressing the engine start button. Once the en- gine has started, release the engine start button, but continue to press the override push button until the warning bell stops. 1.
Before engine start-up, perform the engine pre- trip inspection and daily maintenance checks in Chapter 11 of this manual. 2. Set the spring parking brakes. If the vehicle is equipped with a battery isolator system, and the gel cell battery is completely discharged, press and hold the battery boost push button while pressing the starter push but- ton. This will temporarily disconnect the isolated battery while connecting the engine-starting bat- teries to the ignition switch for engine starting. CAUTION Protect the turbocharger during the start-up by not opening the throttle or accelerating the en- gine above 1000 rpm until normal engine idle oil pressure registers on the gauge. 3.
Set the throttle idle (hold down the clutch pedal). 7. When the engine is started, it takes a while to get the lubricating oil film reestablished between the shafts and bearings, and between the pistons and liners. Bring the engine up to operating speed gradually as it warms up and develops stable oil pressure. 4. Make sure the transmission is in neutral. CAUTION The oil pressure gauge indicates any drop in lu- bricating oil pressure or mechanical malfunction in the lubricating oil system. The operator should note the loss of oil pressure and shut down the engine before damage can occur. Do not crank the engine for more than 30 sec- onds at a time.
Wait two minutes after each try to allow the starter to cool. Failure to do so could cause starter damage. 5. Turn on the ignition switch. 8. During the warm-up period, apply the load gradu- ally until the oil temperature reaches 140°F (60°C). For an engine starting a loaded vehicle, the coolant temperature must be approximately 120°F (49°C). NOTE: A manual override knob, provided on the forward end of the electric shutdown valve, al- lows the valve to be opened in case of electric power failure. To use the override, open it by turning the knob fully clockwise. Return it to the run position after repair. Starting After Extended Shutdown or Oil Change IMPORTANT:
For Detroit Diesel engines, pump- ing the accelerator before or during cranking will not aid in starting. If the engine won’t start, check the main engine power fuses; they may have blown. The fuses are located along the Do the following steps after an oil change or after the engine has been shut down for more than three days: 7.4