Komatsu — CONTROL BOX

OPTIONS, ATTACHMENTS DIRECTION SELECTOR SWITCH This switch is used to change the direction of the cooling fan. This switch is only effective in the manual mode FORWARD: Normal direction of rotation (or machine will overheat) REVERSE: Used for cleaning debris from the surface of the radiator core Set this switch to the FORWARD position normally. If the cooler inlet is clogged with debris, set this switch to the REVERSE position to blow off the debris. REVERSE PILOT LAMP This lamp will keep flashing while the cooling fan is running in reverse. You may hear a ticking sound while this system is operating.

This is normal CONTROL BOX This box houses the electrical components which control the cooling fan direction function. Do not open this box and change any settings. They have been pre-set at the factory. Remark When the fan is in reverse, the cooling fan control box (12) signals the transmission controller to maximize the fan rotation speed. It does this by using the T/C temperature signal. The transmission controller receives the signal and maximizes the angle of the swash plate on the cooling fan pump. The reading on the T/C gauge may climb during the reversal period and not display a true reading. The needle should however, still remain in the white area.

The gauge should return to a true reading as soon as the fan returns to the forward direction. This is no indication of trouble. Engine speed must be 1800 RPM or above to get the cooling fan speed for maximum cleaning ability. WA480-5L 5-29