Komatsu — REPLACEMENT OF GREASE CARTRIDGE

OPTIONS, ATTACHMENTS 9. Repeat steps 6 to 8 to set all the items a, b and c. After completing the setting, press the ESC key to leave the setting mode. Remark Even if it is desired to change only one item, always carry out the setting according to steps 4 to 8. After completing the setting, always press the ESC key to leave the setting mode. If the power is then turned ON, the count for the grease interval will start immediately after the ESC key is pressed. Part of the display segment flashes to indicate that the system is counting. After setting, the set value is retained in the memory even if the power is turned OFF. CHECK THE AMOUNT OF GREASE 1. Turn the starting switch ON 2.

Check the display of the pilot lamp on the machine monitor. If the pilot lamp is flashing at 1-second intervals, it means that the grease cartridge is empty. Replace the grease cartridge with a new cartridge. REPLACEMENT OF GREASE CARTRIDGE Air bleed of the pump involves danger because of high pres- sure. Ask your Komatsu distributor for air bleeding. Be careful of the force applied by spring (2) install inside the cover. Remark After replacing cartridge, be sure to reset number on controller. WA480-5L 5-45