MAINTENANCE COOLANT TESTING FOR CONDITIONER CONCENTRATION When the cooling system is maintained as recommended, the conditioner concentration should be satisfactory. The DCA4 concentration must not fall below 1.0 unit per 3.8 R (1 US gal) or exceed 2 units per 3.8 R (1 US gal) of coolant.The only accurate method for testing chemical concentrations in coolant with mixed chemical compounds is a laboratory analysis. For this reason, the coolant inhibitor should be maintained as shown in "23. MAINTENANCE SCHEDULE CHART". NOTICE: Inadequate concentration of the coolant additive can result in major corrosive damage to cooling system components.
Over concentration can cause formation of "gel" that can cause restriction, plugging of passages and overheating. REPLENISHING COOLANT CONDITIONER Install a "precharge" DCA4 filter when the coolant is changed or a significant (more than 50%) coolant loss occurs. Install a "service" DCA4 filter as specified in "23. MAINTENANCE SCHEDULE CHART" . When antifreeze is added, add coolant conditioner equal to 1.0 unit per 3.8 R (1 US gal) of antifreeze. NOTICE: Mixing of DCA4 and other supplemental coolant additives is not recommended because there is currently no test kit available to measure concentration levels with mixed chemical solutions.
DCA4 UNIT MAINTENANCE GUIDE Use supplemental coolant additives (corrosion inhibitors) to protect the engine cooling system from corrosion. Antifreeze alone does not provide enough corrosion protection for a heavy duty diesel engine. Supplemental corrosion protection must be supplied through periodic additions of supplemental coolant additives to the coolant. To protect against corrosion, a new coolant charge must be brought up to 0.26 DCA4 unit per liter (one unit per U.S. gal) of coolant (initial charge). Maintain the correct DCA4 concentration by changing the service coolant filter at each engine oil and filter change interval.
Each time the coolant is drained and replaced, the coolant must be recharged with supplemental coolant additives. Use the appropriate DCA4 spin-on filter listed in following table. The coolant mixture must be drained and replaced as defined under "General". The amount of replacement inhibitor is determined by the length of the service interval and the cooling system capacity. Refer to the DCA4 Unit Guide for the selection of the correct filter to replenish the DCA4. If coolant is added between drain intervals, additional DCA4 will be required. Check the coolant DCA4 concentration level anytime make-up coolant is added to the system.
The DCA4 concentration must not fall below 0.13 units per liter or exceed 0.5 units per liter (0.5 units per U.S. gallon or exceed 2 units per U.S. gallon). 3-15