24. SERVICE PROCEDURE 24.9.8 CHECK ALTERNATOR, STARTING MOTOR The brush may be worn, or the bearing may have run out of grease, so contact your Komatsu distributor for inspection or repair. If the engine is started frequently, carry out inspection every 1000 hours. 24.9.9 CHECK ENGINE VALVE CLEARANCE, ADJUST As special tool is required for removing and adjusting the parts, request your Komatsu distributor for service. 24.9.10 CLEAN AND CHECK TURBOCHARGER If there is carbon or oil sludge stuck to the blower impeller, it will lower the performance of the turbocharger or cause it to break, so ask your Komatsu distributor to carry out the cleaning.
24.9.11 CHECK PLAY OF TURBOCHARGER ROTOR Ask your Komatsu distributor to check the play of theturbocharger rotor. 24.9.12 CHECK ACCUMULATOR Check the gas pressure of the accumulator as follows. Checking 1. Stop the machine on level ground and apply the parking brake. 2. Raise the work equipment to the maximum height, then place the lift arm control lever at HOLD. 3. Leave the work equipment in this position, and stop the engine. 4. Confirm that it is safe around the machine, then set the lift arm at FLOAT and lower the work equipment to a position 1 m (3.28 ft) from the ground. 5.
When the work equipment reaches a position 1 m (3.28 ft) from the ground, move the lift arm control lever to LOWER, and lower the work equipment slowly to the ground. If the work equipment stops moving during checking, the gas pressure may be below the service limit (0.69 MPa (7 kgf/cm 2 , 99.4 PSI)), so contact your Komatsu distributor to have the gas pressure measured or gas charged. Carry out the checks within 5 minutes of stopping the engine. If the machine is left with the engine stopped, the accumulator pres- sure will drop and it will be impossible to carry out the check. 3-84