Maintenance section Cleaning Primary Filter Elements Air-205 kPa (30 psi) Maximum Pressure Pressure air can cause personal injury. When using pressure air for cleaning, wear a protective face shield, protective clothing and protective shoes. The maximum air pressure must be below 205 kPa (30 psi) for cleaning purposes. NOTICE Direct air on the inside and outside of the element along the length of the pleats. Check the element for any tears, rips or damage. Checking Element Do not clean the elements by bumping or tap- ping them. Inspect filter elements after cleaning. Do not use a filter with damaged pleats, gaskets or seals.
When cleaning with pressure air, use 205 kPa (30 psi) maximum pressure to prevent filter element damage. When cleaning with pressure water, use 280 kPa (40 psi) maximum pressure to prevent fil- ter element damage. Have spare elements on hand to use while cleaning used elements. The primary element should be replaced after 6 months service or after cleaning no more than 3 times. 1. Insert a light inside the clean dry element and examine it. Discard the element if tears, rips or damage are found. 2. Wrap and store good elements in a clean, dry place. 120 WARNING