Doosan GC20SC-5 — Doosan GC20SC-5 User Manual

Maintenance section Hydraulic Oil Level - Check Drive Axle Oil Level - Check Park the lift truck on a level surface. Apply the parking brake. Place the directional control lever in NEUTRAL. At operating temperature, the hydraulic tank is hot and under pressure. Hot oil can cause burns. Remove the fill cap only when the engine is stopped, and the cap is cool enough to touch with your bare hand. Remove the fill cap slowly to relieve pressure. 1. Operate the lift truck for a few minutes to warm the oil. Park the lift truck on a level surface, with the forks lowered, mast tilted back, parking brake engaged, transmission in NEUTRAL and the engine stopped. 1.

Raise the carriage high enough to access the level/fill plug. 2. Pull the latch and raise the hood and seat assembly. Make sure the air lift cylinder securely holds the hood open. 2. Block the bottom of the mast with a block of wood to hold the carriage in the raised position. 3. Turn the ignition switch OFF. 4. Remove the level/fill plug. The oil level should reach the bottom of the hole. Maintain the oil level, to the bottom of the hole. 3. Remove the breather/dip stick. Maintain the oil level to the FULLmark on the breather/dip stick. 5. Clean off the level/fill plug and put it back in place. 6. Remove the wood blocking and lower the load backrest. 121 WARNING