Doosan GC20SC-5 — Doosan GC20SC-5 User Manual

Maintenance section Every 1000 Service Hours or 6 Months You must read and understand the warnings and instructions contained in the Safety section of this manual, before performing any operation or maintenance procedures. Hydraulic Return Filter, Breather & Strainer - Check, Change 4. Remove the return filter from tank top plate assembly. 5. Change the return filter. 6. Remove the suction strainer from the tank. Hot oil and components can cause personal injury. Do not allow hot oil or components to contact skin. 7. Install a new strainer by hand. 8. Install the tank top plate assembly and fasten the bolt. 9.

Start the engine and operate the hydraulic con- trols, and the steering system, through a few cycles to fill the lines. Look for oil leaks. Park the lift truck level with the forks lowered, parking brake engaged, transmission in NEUTRAL and the engine stopped. 1. Remove and discard the air breather. 10. Stop the engine and check the oil level. With all cylinders retracted, maintain the oil level to the FULLmark on the dip stick/filler cap assembly. 2. Install a new air breather. 3. Loosen the bolts of the hydraulic tank top plate assembly. 129 WARNING