MAN — Man Series 40 Engine Operator's Guide

SERIES 40 ELECTRONIC CONTROL SYSTEM * Indicates WARN Lamp on When Fault Set Table 1 Series 40 Diagnostic Flash Codes 32 All information subject to change without notice. (Rev. May 2004) DDC-SVC-MAN-0057 0305 Copyright © 2003 DETROIT DIESEL CORPORATION Flash Code Circuit Description 111 ECM No Errors Detected 112 ECM PWR _ Elec. System Voltage B+ Out of Range HIGH 113 ECM PWR _ Elec. System Voltage B+ Out of Range LOW 114* ECT Eng. Coolant Temp Signal Out of Range LOW 115* ECT Eng. Coolant Temp Signal Out of Range HIGH 121* MAP Intake Manif. Abs. Press Signal Out of Range HIGH 122* MAP Intake Manif. Abs. Press. Signal Out of Range LOW 123* MAP Intake Manif. Abs. Press.

In range Fault 124* ICP Injection Control Press. Signal Out of Range LOW 125 ICP Injection Control Press. Signal Out of Range HIGH 131* APS/IVS Accelerator Position Signal Out of Range LOW 132* APS/IVS Accelerator Position Signal Out of Range HIGH 133* APS/IVS Accelerator Position Signal In range Fault 134* APS/IVS Accelerator Position and Idle Validation Disagree 135* APS/IVS Idle Validation Switch Circuit Fault 141 VSS Vehicle Speed Signal Out of Range LOW 142 VSS Vehicle Speed Signal Out of Range HIGH 143 CMP Wrong Number of CMP Signal Transitions for Cam Rev 144 CMP CMP Signal Noise Deleted