SERIES 40 ENGINE OPERATOR'S GUIDE NOTICE: Under no circumstances should the starting motor and fuel pump be used to prime the fuel filter. Prolonged used of the starting motor and fuel pump to prime the fuel system can result in damage to the starter, fuel pump and injectors and cause erratic running of the engine due to the amount of air in the fuel lines and filter. Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm. Always start and operate an engine in a well ventilated area. 1. Disconnect the CMP (camshaft position sensor) to prevent the engine from starting.

The CMP is installed on the front cover of the engine between the water pump pulley and the fan pulley. See Figure 1. If operating an engine in an enclosed area, vent the exhaust to the outside. Do not modify or tamper with the exhaust system or emission control system. 2. Operate the manual primer pump on the filter header until the primer pump is hard to depress. See Figure 25. NOTICE: To avoid starter damage, do not crank the engine longer than 15 seconds at a time. Allow a 15-second starter cool down interval between starting attempts. 3. Crank the engine three times for 15 seconds each. Reapply the primer pump after each crank cycle. 4.

Once the primer pump is hard to depress (usually three crank and hand prime cycles), reconnect the CMP. 5. Start the engine and check for leaks. Shut down the engine. Correct any leaks with the engine off. All information subject to change without notice. (Rev. May 2004) 83 DDC-SVC-MAN-0057 0305 Copyright © 2003 DETROIT DIESEL CORPORATION