SECTION 4 OPERATING Page 36 LOADER OPERATIONS FLOAT (UPGRADED VERSION) When the float switch is on (Fig. 4.8), the boom will gradually lower. This position is locked with a spring. To shift back to "hold" the switch must be put off. Use the “float" position to follow the contour of the ground when backdragging or leveling hard ground. WARNING! It is forbidden to lower the boom from fully raised position by moving the control lever to “float" position. Due to weight of loader linkage it may be dangerous for nearby personnel and damaging to the machine. 4.17.2. AUTOMATIC BOOM KICK-OUT (Fig. 4.30.) Fig. 4.30. Automatic Boom Kick Out 1. Proximity Switch 2. Adjustment Plate 3. Locking Bolt C.
Plate-to-Switch Clearance The electronically operated kick-out control system stops boom travel automatically at a preselected height. This eliminates unnecessary boom travel during operation and provides for a more efficient cycle. Adjustment plate (2) is bolted to the left boom arm and is adjustable. Proximity switch (1) is mounted to the front frame. Proximity switch (1) creates a magnetic field circuit which is completed by the proximity of adjustment plate (2) within the magnetic field. Once the boom is raised to its preselected height, adjustment plate (2) has moved out of the magnetic field, breaking the circuit.
Breaking the magnetic field circuit causes the boom control lever to move out of the detented "RAISE" position and into the "HOLD" position, thereby stopping the travel of the boom arms. Plate- to-switch clearance "C" necessary for the proper operation of the proximity switch is 7 to 8 [mm]. ADJUSTMENT OF AUTOMATIC BOOM KICK-OUT To change the automatic boom kick-out position, raise the boom arms to the desired stopping height. Place the boom control lever in the "HOLD" position. Loosen locking bolt (3) on sensor plate (2). Move adjustment plate (2) until it is just out of the magnetic field of proximity switch (1). Tighten locking bolt (3) on adjustment plate (2).
Start the machine and test the adjustment. Repeat this procedure until the automatic kick-out height is obtained. WARNING! Use extra caution when adjusting loader’s bucket leveler or boom kick-out. Use two trained people and guard against accidental movement of the machine or loader linkage. No personnel is allowed within the reach of loader linkage. Never work or walk under raised bucket without proper blocking. OM515C520C99/1E DRESSTA